Energieeffizienzklassen (Energy efficiency classes)
- 1 The following definition applies
- 2 Sectors
- 2.1 Boilers and combination boilers (gas/oil/electric)
- 2.2 Water heater (Gas/Oil/Electric)
- 2.3 Climatic and ventilation technology for household
- 2.4 Circulation pumps
- 2.5 Fans
- 2.6 Water pumps
- 2.7 Solid fuel boiler
- 2.8 Household lighting, general lighting
- 2.9 Individual room heaters
- 2.10 Warm air central heating (without CHP)
- 2.11 Climate control, Ventilation technology
The following definition applies
Energetic efficiency is a measure of the energy input required to achieve a defined benefit from products. The labeling of energy consumption for different products serves to support purchasing decisions. It provides information about energy efficiency during use (economic principle). A well-known example of this is the EU energy label for electrical appliances.
According to the EU regulation, for items with the indication of an energy efficiency class, a datasheet must always be provided.
Here is the regulation link https://eur-lex.europa.eu/legal-content/DE/TXT/HTML/?uri=CELEX:32017R1369&from=DE
Sectors
The following sectors with their respective regulations are defined. However, not all energy efficiency classes are currently specified, such as for circulation pumps or fans.
Boilers and combination boilers (gas/oil/electric)
Regulation: VO (EU) 813/2013, VO (EU) 811/2013
Description Energy Efficiency Class | Abbreviation |
---|---|
Class for ‘jahreszeitbedingte Raumheizungs-Energieeffizienz’ (Seasonal Space Heating Energy Efficiency) | jahresz. bed. Raumheizung |
Class for ‘jahreszeitbedingte Raumheizungs-Energieeffizienz Mitteltemperaturanwendungen (55°C)’ (Seasonal Space Heating Energy Efficiency for Medium Temperature Applications (55°C)) | jahresz. bed. Raumheizung mitteltemp. 55C |
Class for 'jahreszeitbedingte Raumheizungs-Energieeffizienz Niedertemperaturanwendungen (35°C)' (Seasonal Space Heating Energy Efficiency for Low Temperature Applications (35°C)) | jahresz. bed. Raumheizung niedertemp. 35C |
Class for ‘Warmwasserbereitungs-Energieeffizienz’ (Warm Water Preparation Efficiency) | Warmwasseraufbereitung |
Class for ‘jahreszeitbedingte Raumheizungs-Energieeffizienz der Verbundanlage aus Raumheizgerät, Temperaturregler und Solareinrichtung’ (Seasonal Space Heating Energy Efficiency of the composite system of space heater, temperature controller, and solar device) | jahresz. bed. Raumheizung Verbundanlage |
Class for jahreszeitbedingte Raumheizungs-Energieeffizienz der Verbundanlage aus Kombiheizgerät, Temperaturregler und Solareinrichtung (Seasonal Space Heating Energy Efficiency of the composite system of combined space heater, temperature controller, and solar device) | jahresz. bed. Raumheizung Verbundanlage |
Class for 'Warmwasserbereitungs-Energieeffizienz der Verbund-anlage aus Kombiheizgerät, Temperaturregler und Solareinrichtung' (Hot water production energy efficiency of the combined system consisting of combination heater, temperature controller, and solar device) | Warmwasseraufbereitung Verbundanlage |
Water heater (Gas/Oil/Electric)
Regulation: VO (EU) 814/2013, VO (EU) 812/2013
Description Energy Efficiency Class | Abbreviation |
---|---|
Class for ‘Warmwasserbereitungs-Energieeffizienz’ (Energy efficiency class for domestic hot water preparation) | Warmwasseraufbereitung |
Energy efficiency class of 'Warmwasserspeicher' (hot water storage tank) | Warmwasserspeicher |
Class for ‘Warmwasserbereitungs-Energieeffizienz der Verbundanlage aus Warmwasserbereiter und Solareinrichtung' (Energy efficiency class for combined hot water preparation system with water heater and solar device) | Warmwasseraufbereitung Verbundanlage |
Climatic and ventilation technology for household
Regulation: VO (EU) 206/2012, VO (EU) 626/2011
Description Energy Efficiency Class | Abbreviation |
---|---|
Class for 'Energieeffizienz Kühlung' (Cooling efficiency class) | Kühlung |
Class for ‘Energieeffizienz Heizung kältere Klimazone’ (Energy Efficiency Heating colder climate zone) | Heizung kältere Klimazone |
Class for 'Energieeffizienz Heizung mittlere Klimazone' (Energy Efficiency Heating moderate climate zone) | Heizung mittlere Klimazone |
Class for ‘Energieeffizienz Heizung wärmere Klimazone’ (Energy Efficiency Heating warmer climate zone) | Heizung wärmere Klimazone |
Circulation pumps
Regulation: VO (EG) 641/2009
Description Energy Efficiency Class | Abbreviation |
---|---|
Not yet defined, possibly Energy Efficiency Index |
Fans
Regulation: VO (EU) 327/2011
Description Energy Efficiency Class | Abbreviation |
---|---|
Not yet defined |
Water pumps
Regulation: VO (EU) 547/2012
Description Energy Efficiency Class | Abbreviation |
---|---|
Not yet defined |
Solid fuel boiler
Regulation: VO (EU) 2015/1189, VO (EU) 2015/1187
Description Energy Efficiency Class | Abbreviation |
---|---|
Energy Efficiency Class for ‘Festbrennstoffkessel' (Solid fuel boiler) | Festbrennstoffkessel |
Energy Efficiency Class for 'Verbundanlage aus einem Festbrennstoffkessel, Zusatzheizgeräte, Temperaturregler und Solareinrichtungen' (System consisting of a solid fuel boiler, additional heating devices, temperature controllers, and solar equipment.) | Verbundanlage |
Household lighting, general lighting
Regulation: VO (EG) 244/2009, VO (EU) 1194/2012, VO (EU) 874/2012, EU-Verordnung 2019/2015
Description Energy Efficiency Class | Abbreviation |
---|---|
Energy Efficiency Class for ‘Lampe’ (lamp) | Lampe |
Energy Efficiency Class for ‘Leuchter genehmigt von/bis’ (Chandelier approved from/to) | Leuchter genehmigt von/bis |
Energy Efficiency Class for ‘LED von/bis’ (LED from/to) | LED von/bis |
Energy Efficiency Class for ‘Lichtquelle’ (2019/2015) (Light Source) | Leuchtmittel 2019/2015 |
Individual room heaters
Regulation: VO (EU) 2015/1188, VO (EU) 2015/1185, VO (EU) 2015/1186
Description Energy Efficiency Class | Abbreviation |
---|---|
Energy Efficiency Class for ‘Einzelraumheizgeräts’ (Individual room heaters) | Einzelraumheizgerät |
Warm air central heating (without CHP)
Regulation: VO (EU) 2016/2281
Description Energy Efficiency Class | Abbreviation |
---|---|
Not yet defined |
Climate control, Ventilation technology
Regulation: VO (EU) 1253/2014, VO (EU) 1254/2014
Description Energy Efficiency Class | Abbreviation |
---|---|
Energy Efficiency Class for ‘Zwei-Richtung-Lüftungsgerät’ (Two-way ventilation unit) | Zwei-Richtung-Lüftungsgerät |
The mapping of energy efficiency classes is done through the attribute system "Regulations" (code "Regulations") and the attribute class "ERP."
Products integrated into different systems are assigned different energy efficiency classes depending on the application:
ArtNr | Attribute system | Attribute class | Attribute name | Attribute value | Attribute value 2 | Attribute unit | Attribute value description |
---|---|---|---|---|---|---|---|
4711 | Regulations | ERP | EEK ‘LED von/bis’ (LED from/to) | A+ | -A+++ |
|
|
4712 | Regulations | ERP | EEK ‘Einzelraumheizgerät’ (Single Room Heater) | A+ |
|
|
|
4713 | Regulations | ERP | EEK 'jahresz. bed. Raumheizung' (Seasonal Space Heating) | A |
|
|
|
4713 | Regulations | ERP | EEK ‘jahresz. bed. Raumheizung | B |
|
|
|
4713 | Regulations | ERP | EEK 'jahresz. bed. Raumheizung | A++ |
|
|
|
4713 | Regulations | ERP | EEK ‘Warmwasseraufbereitung’ (Domestic Hot Water Production) | A |
|
|
|
The information "Attribute unit" and "Attribute value description" must not be provided. The attribute value 2 may only be specified for the energy efficiency classes "Leuchter genehmigt von/bis" and "LED von/bis."